Skip to content
SediLogic Technologies

Wastewater lagoons

Resort wastewater lagoon, Hawaii

A forty-year-old lagoon carrying heavy accumulated solids and an effluent suspended-solids figure the resort could not hold.

Single digits

effluent suspended solids, from a starting figure that was never recorded

Field resultNo method statedConfounded
Duty
Wastewater lagoons
Sector
Municipal
Treatment window
30 days
What was counted
Suspended solids
  • Dosed at 1 ppm of influent flow
  • A fine-bubble aeration system was installed during the same window
Aerial view of a multi-cell aerated wastewater lagoon, its surface broken by aeration, with grass berms dividing the cells and a small control building alongside.
Illustration — an operating aerated lagoon, not the works described on this page.

01The plant

What was being treated

A resort wastewater lagoon roughly forty years old.

02Before

How the material got there

The lagoon had lost the ability to settle out suspended solids. The effluent ran dark green, with heavy growth and floating material blanketing the surface.

03Treatment

What was applied, and how

A thirty-day opening programme with a maintenance dose after it. Fine-bubble diffused aeration was installed over the same period.

Every result in this library was measured at an operating plant treating with one of the formulations SediLogic supplies, over the window stated above. It is a field result published as reported, not a controlled trial we ran.

04Sizing

What the quantity was set against

Set against influent flow rather than lagoon volume, which suits a water-column problem — the target was what was arriving, not what had settled.

05Outcome

What followed

The site manager reported the effluent still improving at the close of the thirty days.

At the start

Dark green effluent, suspended solids very high, heavy surface growth and floating material across the lagoon.

At the close

Suspended solids in single figures to low double figures, the surface growth gone and the effluent clear.

06Limits

What this record does not establish.

No opening suspended-solids figure was published, so the reduction has no arithmetic behind it — 'very high' to 'single digits' is a description, not a measurement. Aeration was installed during the same window, so the result cannot be attributed to the product alone. No method, no laboratory and no untreated comparison are recorded.

Only the volatile organic fraction of a sludge responds to any of this. Grit, sand, silt, mineral precipitates and plastics remain at any dose, here and everywhere else.

What we would supply

For this duty, in our range.

This is the duty SediLogic supplies and sizes. Which article depends on where the material sits: Sedivore Spike is the denser solid and carries down through depth to an established blanket, Sedivore Puck is a smaller unit that spreads a calculated dose across the bed, and SediLogic Maintain is a soluble pouch for load carried in the water column — with Sedivore Polar for that same duty where the water runs cold enough to stall a standard blend.

A quantity for your own lagoon comes from the dosing planner, sized against your dimensions and loading from the manufacturer's written dose method. It does not come from the figure on this page, which was set for a lagoon that is not yours.

Read next

The same duty, measured somewhere else.

  • Wastewater lagoons

    Agricultural lagoon serving 8,000 dairy cows, South America

    Agricultural4 months

    83%

    reduction in total suspended solids

    Field result

    A lagoon loaded well past what it was built for, carrying a foam layer across most of the surface and blocking the irrigation draw.

    • TSS 18,650 mg/L to 3,220 mg/L
    • BOD₅ 5,195 mg/L to 2,752 mg/L, a 47 per cent reduction
    • COD rose over the same period, from 18,211 mg/L to 19,303 mg/L
    • Around 70 per cent of the water surface reported clear of foam
    Suspended solidsBOD and COD
  • Wastewater lagoons

    Swine manure lagoon

    Agricultural6 weeks

    91%

    reduction in total suspended solids

    Field resultThird-party lab

    Suspended solids and phosphorus in a manure lagoon at concentrations that constrained where the contents could go.

    • Phosphorus down 85 per cent
    • COD down 84 per cent
    • Figures attributed to an accredited outside laboratory
    Suspended solidsBOD and COD
  • Wastewater lagoons

    Barbourville, Kentucky

    Municipal24 weeks

    43.3%

    of accumulated solids digested

    Field result

    Just over five feet of accumulated solids in the primary aerated lagoon, assessed at 2,365 dry tons. The plant wanted a route that did not involve dredging.

    • 1,025 dry tons removed
    • Average depth 5.08 ft to 2.65 ft
    Sludge depth and solids

All field results

Your lagoon next

This was measured somewhere else.

A different plant, a different loading and a different sludge. What decides your result is how much of your own accumulation is organic and treatable, and whether the dose is sized against the lagoon in front of us rather than read off this page. Tell us the dimensions and we will size it.